| Key functions |
| Moisture measurement at the core of the sample |
Non invasive (capacitivity/dielectricity), sample mass 250-280g 3-20% wet mass water content Wood pellets, plant pellets |
Non invasive (capacitivity/dielectricity), sample mass 260g 0-55% wet mass water content (conversion to dried matter content possible) Sewage sludge granules -industry sludge, municipal sludge- Two customizable calibrations |
1-100%HR, ±1.5%HR from 10 to 90%HR at 25°C |
| Temperature compensated moisture |
|
|
|
| Temperature measurement at the core of the sample |
|
|
-10-60°C, ±0,3° at 25°/14-140°F, ±0,5° at 77° |
| Ambient humidity measurement |
|
|
1-100%HR, ±1.5%HR from 10 to 90%HR at 25°C |
| Ambient air temperature measurement |
|
|
-10-60°C, ±0,3° at 25°/14-140°F, ±0,5° at 77° |
| Dew point |
|
|
-55-60°C/-67-140°F |
| Data storage |
Manual record (10,000) Measurements, batch number and supplier’s data |
Manual record (10,000) Measurements and supplier’s data |
Manual record (10,000) Measurements and supplier’s data |
| PC connection |
Optional |
Optional |
Optional |
| User interface |
| LCD display |
|
|
|
| Backlighting |
|
|
|
| Measures in °C or °F |
|
|
|
| Menus language(s) |
English, French, Spanish, German, Italian and Russian |
English, French, Spanish, German, Italian and Russian |
English, French, Spanish, German, Italian and Russian |
| Moisture measurement resolution |
0.1% |
0.1% |
0.1% |
| Temperature measurement resolution |
0,5° |
0.5° |
0.1°C/0.3°F |
| Auto off |
After 6 minutes |
After 6 minutes |
After 4 minutes |
| Physical specifications |
| Battery(s) (supplied) |
4 x 1.5V (AA) |
4 x 1.5V (AA) |
4 x 1,5V (AA) |
| Dimensions (H x W x D in mm) |
260 x 70 x 250 |
260 x 70 x 250 |
145 x 63 x 29 (housing) 295 x 20 x 4 (sword sensor) |
| Weight (g) |
1,300 |
1 300 |
260 |
| Storage temperature |
-20-60° C/-4-140°F |
-20-60°C/-4-140°F |
-20-60°C/-4-140°F |
| Operating temperature |
0-40°C/32-104°F |
0-40°C/32-104°F |
-10-60°C/14-140°F |
| Protection (supplied) |
Plastic case |
Plastic case |
Wooden case |
| Electrical protection class |
IP 40 |
IP 40 |
IP 40 |
| Quality |
| Warranty |
2 years |
2 years |
2 years |
| Regulatory compliance |
CE, calibration based on oven drying method (EN 14774) |
CE, calibration based on oven drying method (ISO 712) |
CE |